          在托管、購買服務器或者租用、使用機柜的時候,有時會聽到1U、2U、4U或者42U等類似這樣子的名詞。而這些名詞又代表什么意思呢?跟著快網小編一起來了解一下吧!

          When hosting, purchasing servers, or renting or using server cabinets, sometimes we hear terms like 1U, 2U, 4U, or 42U. And what do these nouns represent? Follow the Quick Net editor to learn more!

          關于“U”的單位U是一種表示服務器外部尺寸的單位,是unit的縮略語。規定了服務器的尺寸,可以使服務器以一定的尺寸放在機架上。機架上有固定服務器的螺孔,以便它能與服務器的螺孔對上號,再用螺絲加以固定好,這樣子可以方便安裝每一部服務器所需要的空間。

          Regarding the unit of 'U', U is a unit that represents the external dimensions of a server and is an abbreviation for 'unit'. The size of the server is specified, which allows the server to be placed on the rack with a certain size. There are screw holes on the rack to fix the server, so that it can match the screw holes of the server, and then be fixed with screws to facilitate the installation of the required space for each server.

          1U 2U 4U 服務器服務器規定的尺寸是服務器的寬(48.26cm=19英寸)與高(4.445cm的倍數),厚度(高度))以4.445cm為基本單位。在機架式服務器尺寸當中,常見的就是1U服務器、2U服務器、4U服務器,這些服務器的尺寸是:1U=4.445厘米,2U=4.445*2=8.89厘米,4U=4.445*4=17.78厘米。在實際使用當中,1U或者2U服務器是經常使用的。因為服務商是根據服務器占用空間來計算費用的,所以采用1U服務器是節省空間的和的,但是1U服務器的擴展性不如2U服務器的好。1U的硬盤數多可以插4個3.5寸,2U可以插8個3.5寸甚更多,另外PCI的插槽數目也不同,1U多2個,2U的可以到6個。base64_image

          The dimensions specified for a 1U 2U 4U server are the width (48.26cm=19 inches) and height (multiples of 4.445cm) of the server, with thickness (height) measured in units of 4.445cm. The common sizes of rack mounted servers are 1U servers, 2U servers, and 4U servers. The dimensions of these servers are: 1U=4.445 centimeters, 2U=4.445 * 2=8.89 centimeters, and 4U=4.445 * 4=17.78 centimeters. In practical use, 1U or 2U servers are the most commonly used. Because service providers calculate fees based on server space occupancy, using a 1U server is the most space saving and cost-effective option. However, the scalability of a 1U server is not as good as that of a 2U server. A 1U hard drive can accommodate up to 4 3.5-inch hard drives, while a 2U can accommodate 8 3.5-inch or even more. Additionally, the number of PCI slots varies, with a maximum of 2 for 1U and up to 6 for 2U.

          42U機柜42U機柜一般的分類是:1)按寬度分:600mm和800mm寬的42U機柜,深度有:600mm,800mm,900mm,960mm,1000mm,1100mm,1200mm等;2)按實際需求分:除了實際使用尺寸是42U之外,寬度和深度可以按照實際需求定制。一個機柜所放的服務器是有限的,42U高度的機柜并不代表著實際能夠放42個1U服務器。放了服務器之后還要留散熱和挪動的空間,一些走線的空間,還有放交換機、防火墻、顯示器等其他設備的空間。所以一個42U機柜能放多少服務器,需要根據具體的設備來計算。那么問題來了,一個機柜一般部署多少臺服務器設備?一個機柜部署的服務器數量,要考慮很多參數,比如服務器的體積、功耗、發熱量等物理參數,還需要考慮機柜的供電、冷卻、承重等參數,如何確定能部署多少臺服務器,做決定時可以參考一下關鍵參數:1)預留:每個設備間預留1U以便散熱,預留交換機位置,考慮PDU位置;2)一般提供冗余10KW電源,靜態承載能力不小于1200kg(根據機房建設參數確定)3)不超電的前提下,一個機柜累計設備U數,一般不超過26U一個機柜,全1U設備部署數量一般不超過16臺,全2U設備一般不超過12臺,全4U設備一般4到7臺。

          The general classification of 42U cabinets is: 1) Divided by width: 600mm and 800mm wide 42U cabinets, with depths of 600mm, 800mm, 900mm, 960mm, 1000mm, 1100mm, 1200mm, etc; 2) According to actual needs: In addition to the actual size of 42U, the width and depth can be customized according to actual needs. The number of servers that can be placed in one cabinet is limited, and a cabinet with a height of 42U does not necessarily mean that 42 1U servers can actually be placed. After installing the server, there should be space for heat dissipation and relocation, some wiring space, and space for other devices such as switches, firewalls, and displays. So how many servers can be placed in a 42U cabinet needs to be calculated based on the specific equipment. So the question is, how many server devices are usually deployed in one cabinet? The number of servers deployed in a cabinet needs to consider many parameters, such as physical parameters such as server volume, power consumption, heat generation, as well as parameters such as power supply, cooling, and load-bearing capacity of the cabinet. When deciding how many servers can be deployed, key parameters can be referred to: 1) Reservation: Reserve 1U between each device for heat dissipation, reserve switch positions, and consider PDU positions; 2) Generally, a redundant 10KW power supply is provided, with a static carrying capacity of not less than 1200kg (determined according to the construction parameters of the computer room). 3) Under the premise of not exceeding the power limit, the cumulative number of equipment U in a cabinet generally does not exceed 26U per cabinet. The deployment of all 1U equipment generally does not exceed 16 units, all 2U equipment generally does not exceed 12 units, and all 4U equipment generally ranges from 4 to 7 units.

          本文由   山東機箱機柜 友情奉獻.更多有關的知識請點擊  http://m.sysghw.cn/   真誠的態度.為您提供為的服務.更多有關的知識我們將會陸續向大家奉獻.敬請期待.

          This article is a friendly contribution from Shandong Chassis Cabinet For more related knowledge, please click http://m.sysghw.cn/ Sincere attitude To provide you with comprehensive services We will gradually contribute more relevant knowledge to everyone Coming soon.

        首頁首頁 產品產品 電話電話 置頂置頂
        主站蜘蛛池模板: 大肉大捧一进一出视频出来呀 | 岛国av网站在线播放| 国产婷婷丁香五月麻豆| 久久亚洲精品情侣| 综合亚洲网| 成人精品视频99在线观看免费| 激情综合网缴情五月天| 喷潮出白浆视频在线观看| 亚洲AV国产福利精品在现观看| 免费99精品国产人妻自在现线| 日韩亚洲国产高清免费视频| 色二av手机版在线| 国产精品无码片在线观看| 人人爽人人爽人人片a免费| 先锋资源久久| 日本高清视频在线一区二区三区| 亚洲av午夜福利精品一级无| 国产亚洲成年网址在线观看 | 亚洲国产精品性色av| 国产av无码专区亚洲aⅴ| 午夜福利国产精品小视频| 97无码免费人妻超级碰碰碰| 中文字幕乱码第一二三区| 免费国产99久久久香蕉| 最新精品露脸国产在线| 99久久er热在这里只有精品99| 亚洲av高清资源在线观看三区| 少妇极品熟妇人妻高清| 毛片无码一区二区三区| 一区二区三区国产美女在线播放| 久久人妻av一区二区三区| 国产精品亚洲一区二区三区正片| 日韩视频无码免费一区=区三区| 黄色软件免费在线观看| A阿V天堂免费无码专区| 国产香蕉尹人综合在线观| 亚洲欧美精品午睡沙发| 久久精品麻豆日日躁夜夜躁妓女| 久久91精品国产91久久麻豆| 亚洲国产香蕉视频欧美| 精品国内综合一区二区|